LC-EM-1283

From LCWIKI
Revision as of 10:14, 7 August 2024 by Melody (talk | contribs) (Created page with "==Product Name== AC-DC Gallium Nitride Isolation Switch Power Module 40W High Current 220V to 12V ==Regarding LC-EM-1283== The LC AC-DC gallium nitride isolation switch...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Product Name

AC-DC Gallium Nitride Isolation Switch Power Module 40W High Current 220V to 12V



Regarding LC-EM-1283

The LC AC-DC gallium nitride isolation switch power module uses Power Integrations' SC1933C as the main control chip,
which can efficiently AC90-250V@50Hz ~60Hz AC power is converted into stable 12V DC power,
and the input end comes with EMI filtering and lightning protection circuit to prevent mutual interference between the power grid and the switching power supply.
The output end supports three wiring methods: screw post, plug-in, and wire bonding


LC-EM-1283 View

LC-EM-1283 Front View

1283-01.jpg

LC-EM-1283 reverse view

1283-02.jpg



Introduction and Explanation

Board size: 60 * 43mm/50g

1283-03.png

Interface Introduction

1283-04.jpg

1. AC90-250V input: KF128-5.08mm-2P terminal (supporting 22-12AWG wires)

2. DC12V output: SMD pads (can be directly soldered)

3. DC12V output: KF128-5.08mm-2P terminal (supporting 22-12AWG wires)

4. DC12V output: XH2.54mm-2P terminal


Functional Features

  • Onboard SC1933C High Efficiency Gallium Nitride Power IC
  • Input voltage: AC90-250V@50Hz-60Hz
  • Output voltage and current: 12V/3.3A
  • Maximum output power: 40W
  • Input terminal: KF128-5.08mm-2P terminal
  • Output terminals: KF128-5.08-2P terminal block, XH2.54mm-2P terminal, SMD pad


Test instructions

The AC input terminal is connected to AC power, and the DC output terminal is connected to the load. The following is the reference data for load testing:

Load current (A) Output voltage (V) Load current (A) Output voltage (V)
0 12.16 1.7 11.85
0.1 12.11 1.8 11.83
0.2 12.11 1.9 11.82
0.3 12.08 2.0 11.81
0.4 12.04 2.1 11.80
0.5 12.03 2.2 11.79
0.6 12.01 2.3 11.78
0.7 11.99 2.4 11.78
0.8 11.96 2.5 11.77
0.9 11.95 2.6 11.76
1.0 11.94 2.7 11.75
1.1 11.93 2.8 11.74
1.2 11.92 2.9 11.73
1.3 11.90 3.0 11.72
1.4 11.88 3.1 11.71
1.5 11.87 3.2 11.70
1.6 11.86 3.3 11.70

Note: The above test results are for reference only. The actual product performance may be close to/better than the above test results (depending on the testing environment)


Safety reminder: As it involves AC220V AC power, please do not touch the circuit board directly with your hands during use
It is recommended to wait for 3 minutes after the power is turned off before taking out the board



Download LC-EM-1283 User Manual

For more information on the use of LC-EM-1283, please refer toBaidu Cloud Drive Extraction code: pn9j